Puncture Probe Micro Inductor Catheter Coil
Miniature Inductor Coil

Puncture Probe Micro Inductor Catheter Coil

Chengpin manufactures micro inductor catheter coils for puncture probes, medical navigation and compact sensing assemblies. Sampling and OEM/ODM development are available after drawing and electrical-target review.

    A puncture probe micro inductor catheter coil is a precision-wound electromagnetic component built into a puncture probe or micro-catheter assembly, where it provides sensing, localization, signal coupling or another electromagnetic function depending on the system design.

    Chengpin winds these coils from ultra-fine wire to customer drawings, controlling the winding window, the core and the lead exit, and supplies them as wound parts or sub-assemblies.

    Product Overview

    A micro inductor catheter coil is one element inside a larger electromagnetic or sensing chain. In a puncture probe it may sit near the tip as a probe sensor coil responding to a field or a moving target. In a micro catheter it may give a localization reference for an electromagnetic tracking system, couple a distal signal to the handle, or form part of a tuned circuit in a compact sensing module. The same coil can serve different duties, so drawing and electrical target are reviewed together.

    These parts serve puncture probe assemblies, minimally invasive catheter systems, navigation hardware, sensing modules and laboratory platforms. They are components for OEMs, not finished medical devices, and Chengpin does not present them as such.

    Coil Structure and Materials

    Each coil is defined by the wire, winding geometry, core or support, insulation and termination, selected together.

    Ultra-fine wire winding

    Fine wire allows a small diameter and a high turn count in a narrow envelope. Chengpin winds enamel-insulated copper and other fine wires down to 0.011 mm where design and material permit, on automatic and semi-automatic equipment with tension control. Turns, pitch and layer build follow the drawing; stepped or non-uniform windings are defined at DFM.

    Core and support options

    Air-core windings give low loss and predictable inductance, suiting higher-frequency work or designs that must stay transparent to an external field. A ferrite core raises inductance in the same footprint and can shape the field, which suits lower-frequency sensing and coupling. Some assemblies need the coil wound onto a customer-supplied tube, mandrel or bobbin to fit the catheter lumen or probe shaft; support geometry and bond areas are reviewed with the winding.

    Insulation, leads and biocompatibility options

    Insulation and coating follow the electrical requirement and the assembly process. Enamel, polyimide, PTFE and parylene-type coatings are available, and the coil can be supplied bare, potted or encapsulated. Medical-grade and biocompatible materials and coatings are options, but the final selection depends on the device, the sterilization method and the regulatory pathway, and is confirmed with the customer. ISO 10993 testing can be arranged on request; the coil is not presented as a certified biocompatible finished device.

    Typical Custom Specifications

    Values come from the drawing and are confirmed at engineering review; the coil is build-to-print, not a catalogue item.

    Parameter Basis for quotation
    Wire diameter Per drawing; down to 0.011 mm where design and material permit
    Coil OD Per drawing, confirmed at review
    Coil ID Per drawing, confirmed at review
    Length Per drawing, confirmed at review
    Inductance Target confirmed at review
    DC resistance / impedance Target confirmed at review
    Operating frequency Per application, confirmed at review
    Turns / pitch Per drawing, confirmed at review
    Core / support Air core, ferrite or customer-supplied support
    Insulation / coating Enamel, polyimide, PTFE or parylene-type, selected at DFM
    Lead / termination Flying leads, solder pads or connector per drawing
    Temperature class Confirmed against material and process
    Tolerance Per drawing, confirmed at DFM

    Applications

    • Puncture probe assemblies. Small coils inside the probe body for tip sensing or positioning.
    • Minimally invasive catheter systems. Wound elements for shafts and distal sections with tight diameter limits.
    • Electromagnetic navigation and localization sensor assemblies. Sensing coils with axes and drive scheme set by the system designer.
    • Medical sensing and signal coupling modules. Inductive parts transferring signal or power across an isolation boundary.
    • Laboratory and preclinical research platforms. Prototype coils for bench rigs and proof-of-concept instruments.

    OEM/ODM and Sample Process

    Every project follows six steps, so drawing, process and inspection method are agreed before winding.

    1. NDA and requirements. NDA signed where required; application, envelope and electrical target collected.
    2. Drawing and electrical review. Envelope and target inductance or impedance checked at the stated frequency.
    3. DFM and material proposal. Comments on wire, core, insulation, termination and hard-to-wind features.
    4. Sample winding. First articles wound on the agreed process and measured against the drawing.
    5. Inspection and test. Dimensions, turns, inductance, resistance and appearance checked, with results reported.
    6. Correction, pilot and production. Deviations corrected, then pilot and volume runs on the same process.

    Samples are built to the customer's drawing. Standard projects are typically sampled in about 3 days, with drawing-to-production validation around 7 days after engineering confirmation, assuming materials are available.

    Quality, Capacity and Certifications

    Chengpin runs a documented quality system across two manufacturing bases, in Pingxiang and Dongguan, and holds ISO 9001, ISO 14001, IATF 16949 and UL E339580 recognition. These describe company systems and process capability, not regulatory approval of this coil.

    • Wire capability. Enamel wire down to 0.011 mm, minimum finished part 1 mm, internal diameters down to 0.19 mm in related work.
    • Process control. 75 quality control points and 12 inspection steps, with an independent reliability laboratory.
    • Equipment. Close to one hundred imported automatic winding machines. The related micro air-core trigger coil line runs at 2 million pieces or more per month, which is not a validated capacity for this product.
    • Handling. Clean handling and controlled cleaning options, with the route agreed per project.

    Why Chengpin for Medical Precision Winding

    A coil that measures correctly is of little use if the material batch cannot be traced or the winding cannot survive overmoulding.

    • Traceable materials. Wire and core batches recorded against the production lot.
    • Verified dimensions. Critical dimensions measured by the DFM method; first-article results travel with samples.
    • Winding and moulding together. Both sit in one group, shortening the loop between a winding change and its housing.
    • Sample to production continuity. Sample and volume parts run on the same process.

    FAQ

    What is the minimum order quantity?
    MOQ is set after engineering review; prototype quantities are supported.

    Can you supply samples?
    Yes, wound to your drawing or an agreed specification.

    What is the sample lead time?
    About 3 days for standard projects after engineering confirmation.

    What wire diameter can you wind?
    Down to 0.011 mm where design and material permit, confirmed at DFM.

    Are biocompatible materials available?
    Medical-grade options exist; the final choice is confirmed against your device and sterilization route.

    Do you provide ISO 10993 testing?
    Testing can be arranged on request; device biocompatibility remains with its manufacturer.

    Can you meet a target inductance or impedance?
    Yes, when the target, test frequency and measurement method are stated.

    Can you supply a partial assembly or connector?
    Yes: wound coil, coil on mandrel, bonded coil or terminated leads.

    What files do you need for an RFQ?
    Drawing or 3D model, coil envelope, electrical target with frequency, material preference, lead definition and annual volume.

    Request a Sample and Engineering Review

    Send the drawing, coil envelope, target inductance or impedance, operating frequency, wire and material preference, lead or connector definition, sterilization and environment information, and expected annual volume. We reply with process comments, a material proposal and a sample plan. For catheter programmes, see our Electrophysiology Catheter Coil.